loveyou88
Active member
BETA-CAE Systems 21.1.6 | 2.2 Gb
Product:BETA CAE Systems
Version:21.1.6
Supported Architectures:x64
Website Home Page :www.beta-cae.com
Languages Supported:english
System Requirements:Windows *
Size:2.2 Gb
BETA CAE Systems announces the release of the 21.1.6 of its software suite. This release arrives as the culmination of our efforts to provide error-proof mechanisms that will safeguard your customization operations and tasks in 21.1.x series.
This last bug-fix release for ANSA/EPILYSIS/META and KOMVOS hosts numerous fixes in recently detected issues, a highlighted selection of which is featured below:
Known issues resolved in ANSA
CAD Import / Export
Thanks to the new library of CT 2021 SP3, unexpected termination regarding SolidWorks and CATPart files has been avoided and special cases with missing color information in CATIA have been successfully addressed. These bug-fixes come to supplement, on top of the existing ones, the support of the following formats:
- NX CR 1980
- Creo 8
- Parasolid 33
CAD to ANSA Translators
- Translation per folder via the -idir option would not succeed in acquiring license for CATIA v4 files.
Data Management
- ANSA could terminate unexpectedly when adapted Subsystems or Group Subsystems that contain adapted Subsystems were saved in DM.
DECKs
- Unexpected termination would occur due to erroneous definition of not Applied A_POINTs entities or when GEB [GEB_GN] entities were attached to Rigid material.
Optimization Tool
- The creation of the session file for a DOE study, through the Post-Processing task item, would not be successful for other than EPILYSIS and Nastran solvers.
Known issues resolved in EPILYSIS
Calculate
- WEIGHTCHECK/GRDPNT would not be calculated correctly in SOL101 case with DMIG (M2GG).
Output
- Unexpected termination would occur in SOL110 with EKE output request.
SOL200
- Unknown conflict would occur in case of ANALYSIS=DFREQ/MFREQ with adjoint response and structural damping.
- Moreover, EPILYSIS would terminate with an error, if USET GRID for MDEXPORT was referenced in an SPC, even if the USET DOF and the SPC DOF were different.
Known issues resolved in EPILYSIS
General
- Deleting a window while animating would cause unexpected termination.
Optistruct
- Shape Optimization results from .op2 files for mode optimization would not be read correctly.
LS-DYNA
- Unexpected termination could occur when Descriptionting curves of Shell Strain output from binout files.
Read Results
- PIDs would not be read correctly in .h5 format from conjugate heat transfer Converge cases, and in Patran formats with 8-digit ID.
NVH Calculators
- OptiStruct FSI DMIG would not be successfully read in Modal Response.
- Fluid structure coupling calculated by META would couple two parallel structural panels instead of just one, if the cavity free surface was positioned between these two panels.
- Modal Response & FRF Assembly: In Fraction (Polar) Descriptions, the Range Type setting would not be respected.
Automation
- Memory leak could occur when using thr script function results.StartChangingCentroidScalar()
BETA CAE Systemsoffers state-of-the-art engineering simulation solutions that meet the requirements of all disciplines, for many sectors, including the automotive motorsports and aerospace. The company's products, the ANSA pre-processor/ EPILYSIS solver and META post-processor suite, and SPDRM, the simulation-process-data-and-resources manager, hold a worldwide leading position across a range of industries, including the automotive, railway vehicles, aerospace, motorsports, chemical processes engineering, energy, electronics, heavy machinery, power tools, and biomechanics.
BETA CAE Systems - simulation solutions
BETA is a simulation solutions provider,dedicated to the development of state of the art software systems. For almost 30 years, BETA has been developing tools and delivering services for the front runners of numerous sectors by listening to their needs and taking up even the most demanding challenges.
Compatibility and Supported Platforms
ANSA files saved by all the first and second point releases of a major version are compatible to each other. New major versions can read files saved by previous ones but not vice versa.
META Project files saved from version 21.1.6 are compatible and can be opened by META version 16.0.0 or later.
Support for 32-bit platform has been discontinued for all operating systems.
Recommend Download Link Hight Speed | Please Say Thanks Keep Topic Live
Code:
Rapidgator
https://rapidgator.net/file/68949fe4a7869f4270e83013c27c8a73/otucu.BETACAE.Systems.21.1.6.part1.rar.html
https://rapidgator.net/file/e5632075bacf9a088b01531f2a01a3f9/otucu.BETACAE.Systems.21.1.6.part2.rar.html
https://rapidgator.net/file/77b4317991966d043164e29361219bcf/otucu.BETACAE.Systems.21.1.6.part3.rar.html
Uploadgig
https://uploadgig.com/file/download/B4859E081210fEa7/otucu.BETACAE.Systems.21.1.6.part1.rar
https://uploadgig.com/file/download/5C32300B3eed38bC/otucu.BETACAE.Systems.21.1.6.part2.rar
https://uploadgig.com/file/download/2a9Fea8b196fc1A4/otucu.BETACAE.Systems.21.1.6.part3.rar
NitroFlare
https://nitro.download/view/98080298CA45236/otucu.BETACAE.Systems.21.1.6.part1.rar
https://nitro.download/view/E1C8795E2678C34/otucu.BETACAE.Systems.21.1.6.part2.rar
https://nitro.download/view/F4C6AAD6FCCEB65/otucu.BETACAE.Systems.21.1.6.part3.rar