Warez.Ge

This is a sample guest message. Register a free account today to become a member! Once signed in, you'll be able to participate on this site by adding your own topics and posts, as well as connect with other members through your own private inbox!

Mehdi Alinoori - Omron PLC Training Course

loveyou88

Active member
1b3d77eb0bdbd2b7dd43d59cf296e430.jpeg

MP4 | Video: h264, 1280x720 | Audio: AAC, 44.1 KHz, 2 Ch
Genre: eLearning | Language: English | Duration: 24 lectures (4h 18m) | Size: 1.46 GB
Programming Omron PLCS by CX-Programmer

What you'll learn
Working with Omron PLC in CX-Programmer Program
Requirements
Have Some Knowledge about PLC
Description
In this course, you can learn about more useful Omron PLC in CX-Programmer.
With CX-Programmer that included in CX-One Package you can Program Below PLC Series
CP1E, CP2E, CP1L, CP1H, CJ2M, CS1
You can download the CX-Programmer Trial Version from Omron Website.
Also after seeing the video you can send any question to me I can answer your questions.
Also, this course can be edited at your request.
Course Details
- DIFU/DIFD
* DIFU(013) turns the designated bit ON for one cycle when the execution condition goes from OFF to ON (rising edge).
* DIFD(014) turns the designated bit ON for one cycle when the execution condition goes from ON to OFF (falling edge).
- TIM/TIMX
* TIM or TIMX(550) operates a decrementing timer with units of 0.1-s.
- CNT/CNTX
* CNT/CNTX(546) operates a decrementing counter.
- KEEP/SET/RSET
* KEEP Operates like a latching relay.
* SET turns the operand bit ON when the execution condition is ON. After this, the specified contact will remain ON regardless of ON/OFF of the input condition.
* RSET turns the operand bit OFF when the execution condition is ON. After this, the specified contact will remain OFF regardless of ON/OFF of the input condition.
- MOV
*Transfers a word of data to the specified word.
- CMP
* Input comparison instructions compare two values (constants and/or the contents of specified words) and create an ON execution condition when the comparison condition is true. Input comparison instructions are available to compare signed or unsigned data of one-word or double-length data.
- CMP/CMPL
* CMP : Compares two unsigned binary values (constants and/or the contents of specified words) and outputs the result to the Arithmetic Flags in the Auxiliary Area.
* CMPL : Compares two double unsigned binary values (constants and/or the contents of specified words) and outputs the result to the Arithmetic Flags in the Auxiliary Area.
- INC/DEC
* Increments the 4-digit hexadecimal content of the specified word by 1.
* Decrements the 4-digit hexadecimal content of the specified word by 1.
- ASL/ASR
* ASL : Shifts the contents of Wd one bit to the left.
* ASR : Shifts the contents of Wd one bit to the right.
- SLD/SRD
* SLD : Shifts data by one digit (4 bits) to the left.
* SRD : Shifts data by one digit (4 bits) to the right.
- BSET
* Copies the same word to a range of consecutive words.
- MOVB
* Transfers the specified bit.
- MOVD
* Transfers the specified digit or digits. (Each digit is made up of 4 bits.)
- NASL/NASR
* NASL : Shifts the specified 16 bits of word data to the left by the specified number of bits.
* NASR : Shifts the specified 16 bits of word data to the right by the specified number of bits.
- MCMP
* Compares 16 consecutive words with another 16 consecutive words and turns ON the corresponding bit in the result word where the contents of the words are not equal.
- MTIM
* Compares 16 consecutive words with another 16 consecutive words and turns ON the corresponding bit in the result word where the contents of the words are not equal.
- TCMP
*Compares the source data to the contents of 16 consecutive words and turns ON the corresponding bit in the result word when the contents of the words are equal.
- TIML
* TIML(542)/TIMLX(553) operates a decrementing timer with units of 0.1s.
- TTIM
* TTIM(087)/TTIMX(555) operates an incrementing timer with units of 0.1-s.
- SETA/RSTA
* SETA(530) turns ON the specified number of consecutive bits.
* RSTA(531) turns OFF the specified number of consecutive bits.
- OUTB
* OUTB(534) outputs the status of the instruction's execution condition to the specified bit.
- XFER
* Transfers the specified number of consecutive words.
- XCHG
* Exchanges the contents of the two specified Words
Who this course is for
Beginner and advanced user
Homepage
Code:
https://www.udemy.com/course/omron-plc-training-course-fa/

Recommend Download Link Hight Speed | Please Say Thanks Keep Topic Live
Code:
https://hot4share.com/tv23czbbahal/ww2bq.O.P.T.C.rar.html
Uploadgig
https://uploadgig.com/file/download/6Bc06ec8789f734E/ww2bq.O.P.T.C.rar
Rapidgator
https://rapidgator.net/file/5e7e7495f17d04da588d92354d079042/ww2bq.O.P.T.C.rar.html
NitroFlare
http://nitro.download/view/58289DB34F23FD4/ww2bq.O.P.T.C.rar
Links are Interchangeable - No Password - Single Extraction
 

Users who are viewing this thread