What's new
Warez.Ge

This is a sample guest message. Register a free account today to become a member! Once signed in, you'll be able to participate on this site by adding your own topics and posts, as well as connect with other members through your own private inbox!

VRV VRF System Pipe Sizing

voska89

Moderator
Staff member
Top Poster Of Month
8c375a5a4e06c36f00d6577cb442dd46.avif

Free Download VRV/VRF System Pipe Sizing
Published 8/2025
MP4 | Video: h264, 1280x720 | Audio: AAC, 44.1 KHz, 2 Ch
Language: English | Duration: 3h 4m | Size: 1.33 GB
Learn VRV Pipe Sizing- Manual & Software​

What you'll learn
Basic of VRV/VRF System
VRV Equipment Selection
Pipe Sizing Manual
Pipe Sizing Software
Requirements
Basic Knowledge of HVAC
Description
Course Title:VRF / VRV System Design and Pipe Sizing (Daikin)Module 1 - IntroductionVRF (Variable Refrigerant Flow) definitionVRV (Variable Refrigerant Volume) definitionTerminology difference (VRV patented by Daikin)Applications & benefitsOne outdoor can connect >60 indoor unitsModule 2 - Components & RefrigerantsCompressors:Digital Scroll CompressorInverter Scroll CompressorRefrigerants: R-410A, R-407C, R-32, R-454BVFD (Variable Frequency Drive) operationPower frequency relation to compressor speedModule 3 - System TypesCooling Only VRFVariable speed scroll compressorElectronic Expansion Valve (EEV)Heat Pump VRFCooling or heating (not simultaneous)Uses 4-way Reversion Valve & NRVHeat Recovery VRF3-pipe systemCooling & heating simultaneouslyModule 4 - Capacity & Piping LimitsCapacity range: 3 TR to 42 TR (10 kW to 150 kW)Max piping length (Daikin example):150 m same level50 m ODU above IDU40 m ODU below IDUDaikin pipe sizing conditions:Max total length = 1000 mMax equivalent length = 190 mMax 13 m branch to last ODUMax 90 m from first indoor branch to farthest IDUMax level difference ODU-IDU = 90 mMax level difference IDUs = 30 mMax level difference ODUs = 5 mModule 5 - Diversity FactorConcept in VRF designNot all IDUs run at full load simultaneouslyExample: 20 HP total indoor load with 15 HP ODUModule 6 - Design Process (Daikin Example)1. Collect project requirements - building survey2. Perform heat load calculation (E-20 Excel, HAP)3. Select indoor units (IDUs)4. Select outdoor unit (ODU)5. Design refrigerant piping layout in AutoCAD6. Perform pipe sizing (manual or software)Module 7 - Pipe Sizing BasicsPurpose:Ensure correct refrigerant flowAvoid oil return issuesMaintain performance & efficiencyPipes: liquid, gas (suction), discharge (heat recovery)Refnet joints/Y-branch connectorsPipe sizing rules:Size increases after each branchDifferent for horizontal/verticalLong run adjustments (>40 m) require 1-step larger pipeModule 8 - Manual Pipe Sizing Steps (Daikin)1. Verify pipe conditions2. Find CI of indoor units & update on Refnet3. Size pipe between Refnet & IDU (Table 5)4. Size pipe from ODU to first Refnet (Table 9 or 10)5. Size pipe between Refnet to Refnet (Table 6 or 7)6. Select outdoor branch kit (Table 4)7. First Refnet from branch kit (Table 3)8. All other Refnet updates (Table 2)Module 9 - Common Issues from Wrong Pipe SizingPoor cooling/heatingOil return failure → compressor damageRefrigerant pressure drop → efficiency lossSystem alarms/trips
Who this course is for
Mechanical, Electrical, Engineers, Architect
Homepage
Code:
https://www.udemy.com/course/vrvvrf-system-pipe-sizing/





Recommend Download Link Hight Speed | Please Say Thanks Keep Topic Live
No Password - Links are Interchangeable
 

Users who are viewing this thread

Back
Top